Guideline:
CSA C22.2, ISO/IEC 11801
YD/T1019-2013
Structure description:
★ Single soft copper conductor
★ Optional insulation materials (solid polyolefin, low-smoke chlorine-free flame-retardant polyolefin)
★ Optional jacket material (polyvinyl chloride, low-smoke chlorine-free flame-retardant polyolefin, fluoropolymer)
★ Optional tear rope
★ Selectable number of pairs
Technical Parameters
Model | Logarithm | Conductor Diameter (mm) | Insulation Diameter (mm) | Cable Outer Diameter (mm) |
CAT6 UTP | 4 | 0.57 | 1.03 | 6.20 |
CAT6 UTP | 8 | 0.57 | 1.03 | 6.2*12.50 |
Electrical performance:
Imbalance of DC resistance ≤2.5%
Insulation resistance ≥5000MΩ·km
Working capacitance ≤5.6nF / 100m
Line-to-ground capacitance imbalance ≤330pF / 100m
Cable installation temperature: 0 ~ 50 ° C
Use
For digital communication, the horizontal cable should have the wiring between the communication terminal of the work area and the distribution frame between the transfers in the building's integrated wiring system, and between the user's communication terminal of the residential integrated wiring system and the distribution frame. Wiring, the standard wiring length of this type of cable is 100m, and it is generally installed by T568A or T568B.
Frequency requirements | Impedance (Ω) | Maximum attenuation value (dB / 100m) | NEXT (dB) Worst pair | DC resistance (100m / 20°C) |
1MHz | 85~115 | 2.1 | 64 | 9.38Ω |
4MHz | 4.3 | 55 | ||
10MHz | 6.6 | 49 | ||
16MHz | 8.2 | 46 | ||
20MHz | 9.2 | 44 | ||
31.25MHz | 11.8 | 42 | ||
62MHz | 17.1 | 37 | ||
100MHz | 22.0 | 34 | ||
250MHz | 18.8 | 30 |
HANGZHOU LINAN YATONG CABLES CO.,LTD